EPA07 MBE 4000 SERVICE MANUAL PERSONAL INJURY To avoid injury from penetrating fluids, do not put your hands in front of fluid under pressure. Fluids under pressure can penetrate skin and clothing. FIRE To avoid injury from fire, keep all potential ignition sources away from diesel fuel, including open flames, sparks, and electrical resistance heating elements. Do not smoke when refueling. 1. Identify the failed electronic unit pump and failure mode (fuel leak at the solenoid). Remove the failed electronic unit pump. Refer to section 2.1.1 for electronic unit pump removal procedure. See Figure 2-8. 1. Stop Plate 5. Intermediate Plate 9. Cross Piece 2. electronic unit pump 6. Magnet 10. O-ring 3.
Anchor Plate 7. Screw 11. O-ring 4. Seal 8. Model Plate Figure 2-8 electronic unit pump Components 2. Wipe the pump clean, removing excess fuel. 3. Remove the O-rings from the electronic unit pump. Push the electronic unit pump O-ring installer (J–45373) onto the electronic unit pump. This will prevent dirt from entering the electronic unit pump holes. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-11