Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 3. Using a 36-mm socket, unscrew the cap on the fuel filter. Lift both the cap and the filter element a short distance above the filter housing. Allow the fuel to drain off the filter into the housing. See Figure 2-32. 1. Washers 9. Fuel Filter Housing 2. Banjo Bolt 10. Filter Element 3. Fuel Supply Line to HC Doser 11. O-ring 4. Fuel Delivery Line to Main Gallery 12. Fuel Filter Cap 5. Banjo Fitting 13. Bracket Mounting Bolts 6. Fuel from Pump to Filter 14. Fuel Filter Housing Mounting Bracket 7. Priming Nipple Valve 15. Fuel Filter Housing-to-Bracket Mounting Bolts 8. Dust Cover 16.

Fuel Drain Line (return to tank) Figure 2-32 Engine Fuel Filter Housing All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-51