EPA07 MBE 4000 SERVICE MANUAL 2. Using a 36-mm socket, unscrew the cap and filter and allow the oil to drain into the housing. After draining, remove the assembly from the housing. See Figure 3-20. 1. Oil Filter Housing 3. O-ring 2. Oil Filter Cap Figure 3-20 Oil Filter Element 3. Remove the element by pressing and twisting the side and detaching it from the cap. 4. Remove the oil filter O-ring and discard it. Lightly lubricate a new O-ring with engine oil and install it on the filter cap. 5. Check the filter housing for any debris. 6. Insert a new filter element into the cap. 7. Insert the element and cap assembly into the housing. Torque the cap to 25 N·m (18 lb·ft).
ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 8. Start the engine and check for leaks. 9. Stop engine and wait 10 minutes and check the engine oil level and add oil if necessary. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 3-23