4.2 COOLANT PUMP 6. Measure the gap between the impeller and the coolant pump housing. This gap, listed in Table 4-4, must be more than 0.6 mm (0.024 in.) and less than 1.0 mm (0.039 in.). See Figure 4-9. Table 4-4 Critical Dimension for Coolant Pump 1. Impeller 2. Coolant Pump Housing Figure 4-9 Gap Between the Impeller and the Housing 7. Rotate the coolant pump drive shaft to make sure it moves easily and freely. 8. Install the coolant pump on the engine. 4.2.4 Installation of Coolant Pump Installation steps are as follows: 1. Install the thermostats. Refer to section 4.4.2. 2. Install the coolant pump and new gasket on the cylinder block. Tighten the mounting bolts to 30 N·m (22 lb·ft).
3. Install EGR cooler coolant return tube. Refer to section 8.6.2. 4. For engines equipped with the Extreme Cold Climate (EC2) Package, install the coolant return line from the air intake manifold to the coolant pump. Torque to 50 N·m (37 lb·ft). 5. Connect the inlet pipe to the coolant pump housing, as removed. Install a new gasket on the mating surface between the inlet pipe and the coolant pump housing. Tighten the inlet pipe mounting bolts to 50 N·m (37 lb·ft). All information subject to change without notice. 4-16 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION Description mm (in.) Gap Between the Impeller and the Coolant Pump Housing 0.6-1.0 (0.024-0.039)