EPA07 MBE 4000 SERVICE MANUAL 6. Install the upper coolant tube onto the thermostat housing. 7. Secure the coolant pump pulley to the coolant pump. Torque the bolts to 25 N·m (18 lb·ft). 8. Move the front idler and tensioner support back into place on the cylinder block. Tighten the mounting bolts to 60 N·m (44 lb·ft). 9. Release the belt tensioners for the main drive and fan belts. Route the two belts around their pulleys and restore the belt tension. 10. Install the fan on the coolant pump pulley. Torque the bolts to 25 N·m (18 lb·ft). 11. Secure the front engine lifting bracket to the coolant pump and EGR valve. Torque the bolts to 50 N·m (37 lb·ft). 12.
Secure the EGR valve cover plate to the EGR valve and the front lifting bracket. Torque the bolts to 25 N·m (18 lb·ft). 13. Fill the engine with coolant, as removed, and check for leaks. The cooling system capacity is listed in Table 4-1. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 4-17