Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

8.3 EGR COOLER AND SUPPORT BRACKET 8.3.1.1 Testing of EGR Cooler Leak Testing steps are as follows: 1. Install air supply fitting (J–47192–1, part of toolset (J–47192)) and seal washer in the EGR cooler at the vent line port. See Figure 8-7. 2. Attach the two plugs (J-47313–3, part of toolset (J–47192)) to the coolant inlet and outlet tubes on the EGR cooler and secure the plugs with hose clamps. Tighten the clamps securely. See Figure 8-7 for details. 1. Hose Clamp 4. Shut-off Valve 2. Regulator Valve 5. Seal Washer 3. Regulator Knob 6. EGR Cooler Figure 8-7 EGR Cooler Test Set-Up 3.

Connect the pressure hose (J–47313–2, part of toolset (J–47192)) to regulator and gauge (J–45982–7, part of toolset J–45982) to the EGR cooler vent line. See Figure 8-7. 4. Check and ensure the shutoff valve is in the OFF position. 5. Set the regulator to zero pressure by pulling upward on the adjusting knob and turning in a counterclockwise direction until it stops. 6. Connect a shop air supply to the pressure regulator and open the shutoff valve. All information subject to change without notice. 8-12 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION