EPA07 MBE 4000 SERVICE MANUAL EYE INJURY To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. 7. Adjust the system pressure by pulling the adjusting knob upward and turning clockwise until a pressure is set to 90 kPa (13 psi). NOTE: Do not connect the pressure hose (J–47313–2) to the air supply fitting (J–47192–1) on the EGR cooler until the pressure has been adjusted to 90 kPa (13 psi). 8. Once the pressure has been set to 90 kPa (13 psi), connect the pressure hose to the vent line fitting on the cooler.
BURNS To avoid injury from burning, use lifting tools and heat-resistant gloves when handling heated components. 9. Submerge the EGR cooler completely in a hot water tank. Tip one end of the cooler up so that air bubbles will quickly escape. 10. Leave the EGR cooler submerged for five minutes. 11. If a steady stream of small air bubbles will come out of the highest end of the EGR cooler the cooler is faulty and must be replaced. 12. Turn OFF the regulator valve, remove the shop air supply, and slowly turn ON the regulator valve to relieve the residual pressure from the EGR cooler. 13. Remove the EGR cooler test kit components from the EGR cooler.
8.3.2 Installation of EGR Cooler Installation steps are as follows: All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 8-13