8.3 EGR COOLER AND SUPPORT BRACKET 1. Coat the connector pipe on the EGR cooler outlet pipe with International Product Corporation Rubber Lubricant Emulsion (P-80) and insert the connector pipe and outlet pipe into the coolant inlet pipe on the water pump. See Figure 8-8. 1. Bolts 5. Connector Pipe 2. Gasket 6. Bolt 3. Upper Coolant Inlet Pipe 7. Lower Coolant Inlet Pipe 4. EGR Cooler Figure 8-8 Coolant Inlet Pipe 2. If removed, install a new gasket and the EGR coolant inlet pipe to the cylinder block and secure with two bolts. Torque bolts to 35 N·m (26 lb·ft). See Figure 8-8. All information subject to change without notice. 8-14 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION