EPA07 MBE 4000 SERVICE MANUAL 5. Remove the dust cover from the priming valve and connect the line from the primer tank to the priming valve on the secondary fuel filter. Close the valve on the priming line. See Figure 12-4 1. Dust Cap 3. Priming Nipple Valve 5. Fuel Delivery line 2. Valve 4. Secondary Fuel Filter Figure 12-4 Priming the Fuel Filter 6. Pump the primer tank numerous times to build up pressure. 7. Open the valve on the priming line and wait 60 seconds for system to fill. 8. Crank the engine for 30 seconds at a time, but no longer. Before cranking the engine again, wait at least two minutes. The engine should start within four 30-second attempts. 9.
Once the engine starts and runs smoothly, close the valve and disconnect the priming line from them the priming nipple valve on the secondary fuel filter. Install the dust cap on the priming nipple valve. 10. Slowly release the pressure on the diesel fuel system primer (J–47912) by slightly turning the pumping handle counter-clockwise. 11. With the engine running, check the fuel filter for leaks. Repair any leaks found. 12. Shut down the engine. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 12-7