Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

12.3 RUNNING THE ENGINE 2. To increase the idle speed, push the "Resume" switch until the idle is fast enough. 3. To decrease the idle speed, push the "Decel" switch until the idle is slow enough. 12.3.5 Emergency Running Mode The engine is equipped with the electronic engine control system, which monitors the engine as it is running. As soon as a fault is detected, it is evaluated and one of the following measures is initiated. NOTICE: To prevent possible serious engine damage, have any faults corrected without delay by an authorized dealer.

In conjunction with any dashboard or instrument panel display, the code for the electronic control unit reporting the fault can be read immediately on the display. Complete fault codes are transmitted and can be read using DDDL® 7.0 or latest version. If the fault is serious enough to impair normal operation, the electronic engine system switches over to emergency running mode. When in emergency running mode, the engine operates at a constant 1300 rpm. This allows you to move the vehicle to a service location. For fault codes and their meanings, see the DDEC VI MBE 4000 Troubleshooting Guide (6SE568). All information subject to change without notice.

12-12 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION