Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

14.1 SCHEDULED INTERVALS HOT COOLANT To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. NOTE: Check and correct the coolant level only when the coolant temperature is below 50°C (122°F). 1. Open the cap on the surge tank slowly, to allow excess pressure to escape. Set the cap aside. 2. Before adding coolant, use a suitable tester to check the concentration of corrosion-inhibiting antifreeze.

If the concentration is lower than 50 percent by volume, drain coolant/add antifreeze until the concentration is correct. The coolant mixing ratio is listed in Table 14-5. *Concentrations of 60 percent affords the maximum antifreeze protection. Higher concentrations adversely affect heat dissipation. Table 14-5 Coolant Mixing Ratio NOTE: When topping off, use only a pre-prepared coolant mixture containing a 50 percent concentration by volume of corrosion-inhibiting antifreeze. NOTICE: If the concentration of antifreeze is too low, there is a risk of corrosion or cavitation in the cooling system. 3. Check the coolant level and add more coolant if necessary.

14.1.7 Coolant Inhibitor Test Intervals Coolant inhibitor level should be checked at the intervals listed in Table 14-6. If topping off is needed, add coolant which is identical to the initial fill coolant. All information subject to change without notice. 14-16 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION Antifreeze Protection Down to °C (°F) Water Percentage by Volume Corrosion-Inhibiting Antifreeze Percentage by Volume –37 (–34) 50 50 –52(–62) 40 Maximum 60*