Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

14.1 SCHEDULED INTERVALS 14.1.8 Inhibitor Level Checking Use Detroit Diesel POWER Trac ® 3–way Coolant Test Strips to measure nitrite and glycol concentrations. Cavitation/corrosion protection is indicated on the strip by the level of nitrite concentration. Freeze/boil-over protection is determined by glycol concentration. Check the inhibitor level as follows: HOT COOLANT To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. 1.

Dip the test strip into the coolant for one second, then remove it. Shake the strip vigorously to remove excess liquid. 2. Immediately compare the end pad to the color chart on the container to determine the glycol concentration. 3. Sixty seconds (one minute) after dipping, compare the nitrite pad to the color chart on the container to determine the nitrite concentration. 4. If the additive indicator (middle pad) shows any color change, this indicates the presence of an unauthorized inhibitor. 5. If any problems exist, change the coolant. 6. After each use, replace and tighten the cap on the test strip container. Discard any test strips that have turned light pink or tan in color. 7.

Close and tighten the cap on the surge tank. A factory coolant analysis program is available through authorized Detroit Diesel service outlets. 14.1.9 Coolant Flushing and Changing Flush and change the coolant as follows: All information subject to change without notice. 14-18 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION