Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

15.1 PREPARING ENGINE FOR STORAGE 18. Seal all engine openings, including the exhaust outlet, with moisture-resistant tape. Use cardboard, plywood or metal covers where practical. 19. Clean and dry the exterior painted surfaces of the engine and spray with a suitable liquid automobile body wax, a synthetic resin varnish, or a rust preventive compound. 20. Protect the engine with a good weather-resistant tarpaulin and store it under cover, preferably in a dry building which can be heated during the winter months. Outdoor storage of the engine is not recommended. If units must be kept out of doors, follow the preparation and storage instructions already given.

Protect units with quality, weather-resistant tarpaulins (or other suitable covers) arranged to provide for air circulation. NOTICE: Do not use plastic sheeting for outdoor storage. Plastic is fine for indoor storage. When used outdoors, however, enough moisture can condense on the inside of the plastic to rust ferrous metal surfaces and pit aluminum surfaces. If a unit is stored outside for any extended period of time, severe corrosion damage can result. The stored engine should be inspected periodically. If there are any indications of rust or corrosion, corrective steps must be taken to prevent damage to the engine parts.

Perform a complete inspection at the end of one year and apply additional treatment as required. 15.1.7 Procedure for Restoring to Service an Engine that Has Been in Extended Storage If an engine has been in extended storage, prepare it for service as follows: 1. Remove the covers and tape from all the openings of the engine, fuel tank and electrical equipment. Do not overlook the exhaust outlet. 2. Remove the plugs from the inlet and outlet fuel lines and reconnect the lines to their proper positions. 3. Wash the exterior of the engine with fuel oil to remove the rust preventive. Do not wash electrical components. 4. Remove the rust preventive from the flywheel.

Flush any soluble oil rust inhibitor (if used) in the cooling system. 5. Remove the paper strips from between the pulleys and drive belts. 6. Fill the crankcase to the proper level with the required grade of lubricating oil. Use a pressure lubricator to insure all bearings and rocker shafts are lubricated. 7. Fill the fuel tank with the required fuel. 8. Close all drain cocks and fill the engine cooling system with clean, soft water and required inhibitors. If the engine is to be exposed to freezing temperatures, install genuine Detroit Diesel Power Cool antifreeze or an equivalent ethylene glycol-base or propylene All information subject to change without notice.

15-8 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION