EPA07 MBE 4000 SERVICE MANUAL glycol-base antifreeze solution which provides required freeze, boil over, and inhibitor protection. 9. Install and connect the battery. Make sure the average specific gravity of the battery is 1.260 or higher. Charge the battery, if necessary. 10. Service the air cleaner, if required. 11. Transmission: Follow the manufacturer's recommendations covering the return of the transmission to service. 12. Power Take-Off: If equipped, follow the manufacturer's recommendations covering the return of the power take-off to service. 13. Turbocharger: Remove the covers from the turbocharger air inlet and turbine outlet connections. Reconnect piping as required.
Prelube the turbocharger center bearing housing. ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 14. After all preparations are completed, start the engine. NOTE: The small amount of rust preventive which remains in the fuel system will cause smoky exhaust for a few minutes. NOTE: Before subjecting the engine to a load or high speed, allow it to reach normal operating temperature. Then check for trouble codes. 15.1.8 Extended Storage (More Than 12 months) To prepare an engine for extended storage (more than 12 months), follow this procedure: 1. Drain the cooling system. 2. Flush with clean, soft water.
3. Refill with clean, soft water and add a rust inhibitor to the cooling system. Refer to section 14.1.9. 4. Circulate the coolant by operating the engine until normal operating temperature is reached. 5. Stop the engine. 6. Install new lubricating oil filters. Refer to section 14.1.5. All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 15-9