15.1 PREPARING ENGINE FOR STORAGE 7. Fill the crankcase to the proper level with Tectyl® 390A preservative lubricating oil or an equivalent 30–weight preservative lubricating oil meeting MIL–L–21260C, Grade 2 specification. 8. Drain the fuel tank. 9. Refill with enough clean No. 1 diesel fuel or pure kerosene to permit the engine to operate for about ten minutes. If it is not convenient to refill the fuel tank, use a separate, portable supply of recommended fuel. NOTE: If engines in vehicles are stored where condensation of water in the fuel tank may be a problem, supplemental additives containing methyl carbitol or butyl cellusolve are effective.
Follow the manufacturer's instructions for their use. The use of isopropyl alcohol is no longer recommended due to its negative effect of fuel lubricity. NOTE: In environments where microbe growth is a problem, a fungicide such as Biobor® JF (or equivalent) may be used. Microbial activity may be confirmed with commercially available test kits. Follow the manufacturer's instructions for treatment. Avoid the use of fungicides containing halogenated compounds, since these may cause fuel system corrosion. 10. Drain the fuel system. 11. Replace the fuel filters. Refer to section 14.1.2 and Refer to section 14.1.3.
ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 12. Operate the engine for five minutes to circulate the clean fuel oil throughout the engine. Ensure the engine fuel system is full. 13. Disconnect the fuel return line and the inlet line at the primary filter and securely plug both lines to retain the fuel in the engine. 14. Service the air cleaner. 15. To prepare the transmission, power take–off and turbocharger: [a] Follow OEM recommendations for prolonged storage to store the transmission. [b] Follow OEM recommendations for prolonged storage to store the power take–off.
[c] Since turbocharger bearings are pressure lubricated through the external oil line leading from the oil filter adaptor while the engine is operating, no further attention is required; however, the turbocharger air inlet and turbine outlet connections should be sealed off with moisture resistant tape. All information subject to change without notice. 15-10 DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION