EPA07 MBE 4000 SERVICE MANUAL 6. Check the crankshaft for dynamic balance. Permissible imbalance is listed in Table 1-13. 7. Using a micrometer, measure the diameters of the main journals and the connecting-rod journals. Measure in both the vertical and horizontal directions on each journal. Refer to section 1.10.2.2 for detailed procedures. 8. Comparing the two measurements taken above, check each crankshaft main and connecting-rod journal for out-of-round. If, for any one journal, the two measurements differ by more than 0.01 mm (0.0004 in.), regrind the crankshaft. If, for any one journal, the two measurements differ by more than 0.02 mm (0.0008 in.), replace the crankshaft.
Refer to section 1.10.1. Listed in Table 1-14 are the permissible ranges at the various repair stages. Table 1-14 Crankshaft Journal Diameters 9. Measure the width of all the main and connecting-rod journals. See Figure 1-60. Listed in Table 1-15 are the permissible ranges. 1. Crankshaft 2. Hardness Tester Figure 1-60 Journal Measurements All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 1-71 Size: mm (in.) Main Bearing Journal Diameter: mm (in.) Connecting-Rod Bearing Journal Diameter:
mm (in.) Standard 103.980-104.000 (4.0937-4.0945) 93.980-94.000 (3.7000-3.7007) Undersize - 0.10 (0.004) 103.880-103.900 (4.0898-4.0905) 93.880-93.900 (3.6960-3.6968) Undersize - 0.25 (0.010) 103.730-103.750 (4.0839-4.0846) 93.730-93.750 (3.6901-3.6909) Undersize - 0.50 (0.020) 103.480-103.500 (4.0740-4.0748) 93.480-93.500 (3.6803-3.6811) Undersize - 0.75 (0.030) 103.230-103.250 (4.0642-4.0650) 93.230-93.250 (3.6705-3.6712) Undersize - 1.00 (0.040) 102.980-103.000 (4.0543-4.0551) 92.980-93.000 (3.6606-3.6614)