3. Install two adjusting screws. 4. Line up flat gasket (Arrow) and housing cover (Figure 57). Now, bring housing cover using adjusting screws uniformly against shoulder (Figure 58). Figure 57 Figure 58 5. Preload spool and remove the cylindrical pins (assembly aid) again. Figure 59 6. Fasten housing cover using socket head screws. NOTE: Torque limit 5.5 Nm (4 ft lb). Figure 60 S0607080K Page 52 Transmission and Torque Converter (ZF 4WG-310)