S0607900C Page 13 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 26 S.C. to ground at transmission sump temperature sensor input. The measured voltage is too low: • Cable is defective and is contacted to vehicle ground. • Temperature sensor has an internal defect. • Connector pin is contacted to vehicle ground. No reaction, TCU uses default temperature. OP-Mode: normal. Check cable from TCU to sensor. Check connectors. Check temperature sensor. --------------- 31 S.C. to battery voltage or O.C. at engine speed input.
TCU measures a voltage higher than 7.00 V at speed input pin. • Cable is defective and is contacted to battery voltage. • Cable has no connection to TCU. • Speed sensor has an internal defect. • Connector pin is contacted to battery voltage or has no contact. OP-Mode: substitute clutch control. Check cable from TCU to sensor. Check connectors. Check speed sensor. --------------- 32 S.C. to ground at engine speed input. TCU measures a voltage less than 0.45V at speed input pin. • Cable / connector is defective and is contacted to vehicle ground. • Speed sensor has an internal defect. OP-Mode: substitute clutch control. Check cable from TCU to sensor. Check connectors. Check speed sensor.
--------------- * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.