Daewoo Heavy Industries Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 14 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 33 Logical error at engine speed input. TCU measures a engine speed over a threshold and the next moment the measured speed is zero. • Cable / connector is defective and has bad contact. • Speed sensor has an internal defect. • Sensor gap is incorrect. OP-Mode: substitute clutch control. Check cable from TCU to sensor. Check connectors. Check speed sensor. Check sensor gap. This fault is reset after power up of TCU. 34 S.C. to battery voltage or O.C. at turbine speed input.

TCU measures a voltage higher than 7.00 V at speed input pin. • Cable is defective and is contacted to battery voltage. • Cable has no connection to TCU. • Speed sensor has an internal defect. • Connector pin is contacted to battery voltage or has no contact. OP-Mode: substitute clutch control. If a failure is existing at output speed, TCU shifts to neutral. OP-Mode: limp home. Check cable from TCU to sensor. Check connectors. Check speed sensor. --------------- 35 S.C. to ground at turbine speed input. TCU measures a voltage less than 0.45V at speed input pin. • Cable / connector is defective and is contacted to vehicle ground. • Speed sensor has an internal defect. OP-Mode:

substitute clutch control. If a failure is existing at output speed, TCU shifts to neutral. OP-Mode: limp home. Check cable from TCU to sensor. Check connectors. Check speed sensor. --------------- * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.