S0607900C Page 24 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 94 ** S.C. to ground at relay starter interlock. TCU detected a wrong voltage at output pin, that looks like a S.C. to vehicle ground. • Cable is defective and is contacted to vehicle ground. • Starter interlock relay has an internal defect. • Connector pin is contacted to vehicle ground. No reaction. OP-Mode: normal. Check cable from TCU to starter interlock relay. Check connectors from starter interlock relay to TCU. Check resistance 1) of starter interlock relay.
1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 95 * O.C. at LIS1 solenoid valve. The measured resistance value of the valve is out of limit. • Cable/connector is defective and has no contact to TCU. • Valve has an internal defect. No reaction. OP-Mode: normal. Check the cable from TCU to the valve. Check the connectors from valve to TCU. Check the valve resistance. If fault code 95 and 98 are both being displayed for about one second each, see combined fault code. 95 ** S.C. to battery voltage at relay starter interlock. TCU detected a wrong voltage at output pin, that looks like a S.C. to battery voltage.
• Cable is defective and is contacted to battery voltage. • Starter interlock relay has an internal defect. • Connector pin is contacted to battery voltage. No reaction. OP-Mode: normal. Check cable from TCU to starter interlock relay. Check connectors from starter interlock relay to TCU. Check resistance 1) of starter interlock relay. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 95 * 98 * Each fault code shown for about one second. S.C. battery voltage or ground at LIS1 solenoid valve or LIS2 solenoid valve. • Cable is defective and is contacted to vehicle ground or vehicle ground. • Cable has no connection to TCU. • Valve has an internal defect.
• Connector pin is contacted to battery voltage or is broken. • Connector pin is contacted to vehicle ground. No reaction. OP-Mode: normal. Check the cable from TCU to the valve. Check the connector. Check the valve. --------------- * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.