S0607900C Page 25 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 96 ** O.C. at relay starter interlock. TCU detected a wrong voltage at output pin, that looks like a O.C. for this output pin. • Cable is defective and has no connection to TCU. • Starter interlock relay has an internal defect. • Connector has no connection to TCU. No reaction. OP-Mode: normal. Check cable from TCU to starter interlock relay. Check connectors from starter interlock relay to TCU. Check resistance 1) of starter interlock relay.
1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 98 * O.C. at LIS2 solenoid valve. The measured resistance value of the valve is out of limit. • Cable/connector resistance and has no contact to TCU. • Valve has an internal defect. No reaction. OP-Mode: normal. Check the cable from TCU to the valve. Check the connectors from valve to TCU. Check the valve resistance. If fault code 95 and 98 are both being displayed for about one second each, see combined fault code. B1 Slippage at clutch K1. TCU calculates a differential speed at closed clutch K1. If this calculated value is out of range, TCU interprets this as slipping clutch. • Low pressure at clutch K1.
• Low main pressure. • Wrong signal at internal speed sensor. • Wrong signal at output speed sensor. • Sensor gap is incorrect. • Clutch is defective. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check pressure at clutch K1. Check main pressure in system. Check sensor gap at internal speed sensor. Check sensor gap at output speed sensor. Check signal at internal speed sensor. Check signal at output speed sensor. Replace clutch. --------------- * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.