Komatsu — INITIAL 250 HOURS MAINTENANCE (ONLY AFTER THE FIRST 250 HOURS)

MAINTENANCE MAINTENANCE PROCEDURE Adjustment There is danger of plug (1) flying out under the high inter- nal pressure of the grease. Never loosen plug (1) more than 1 turn. Never loosen any part other than plug (1). Never put your face in the mounting direction of plug (1). If the track tension cannot be loosened with the proce- dure given here, please contact your Komatsu distributor. When increasing tension Prepare a grease gun. 1. Pump in grease through grease fitting (2) with a grease gun. 2. To check that the tension is correct, move the machine slowly forward (7 - 8 m). 3. Check the track tension again, and if the tension is not correct, adjust it again. 4.

Continue to pump in grease until dimension S becomes zero (0). If the tension is still loose, the pin and bushing are excessively worn, so they must be either turned or replaced. Please contact your Komatsu distributor for repairs. 237 WARNING