OPERATION EXPLANATION OF COMPONENTS SELECT SWITCH This switch (7) is used to select the hydraulic flow setting in each of the working modes A, E, and B. When the working mode is A or E 1. Press select switch (7) and the normal screen on the monitor display changes to the flow setting screen shown in the diagram on the right. 2. Press up switch (9) or down switch (10) to adjust to the desired flow. Each segment on the scale is approx. 30 liters/min. 3. After completing the flow setting, press input confirmation switch (11). The monitor display will return to the normal screen. REMARK The flow can be adjusted for the attachment installed. When the working mode is B mode 1.
Press select switch (7) and the normal screen on the monitor display changes to the flow setting screen shown in the diagram on the right. 02 03 1 1 1 230 01 2. Press up switch (9) or down switch (10) to adjust to the desired flow. 150 190 min min 3. After completing the flow setting, press input confirmation switch (11). N0 01 4. With the operation in Step (3), the flow setting screen changes to the fine flow adjustment screen shown in the diagram on the right. 5. Press up switch (9) or down switch (10) to adjust to the desired flow. Each segment on the scale is approx. 10 liters/min. 6. After completing the flow setting, press input confirmation switch (11).
The monitor display will return to the normal screen. 83