Fusible Link The fusible link is primarily used to protect circuits where high amounts of current flow and where is would not be practical to use a fuse. For example, the starter circuit. When a current overload occurs, the fusible link melts open and interrupts the flow of current so as to prevent the rest of the wiring harness from burning. Determine the cause of the overload before replacing the fusible link. The replacement fusible link must have the same amperage specification as the original fusible link. Never replace a blown fusible link with fusible link of a different amperage specification. Doing so can result in an electrical fire or other serious circuit damage.
A blown fusible link is easily identified. N8A0027E Fusible Link Specifications Circuit Breaker The circuit breaker is a protective device designed to open the circuit when a current load is in excess of rated breaker capacity. If there is a short or other type of over- load condition in the circuit, the excessive current will open the circuit between the circuit breaker terminals. The reset knob pops out when the circuit is open. Push the reset knob in place to restore the circuit after repair- ing it. Relay Battery and load location may require that a switch be placed some distance from either component. This means a longer wire and a higher voltage drop 1.
The installation of a relay between the battery and the load reduces the voltage drop 2. Because the switch controls the relay, amperage through the switch can be reduced. N8A0029E N8A0028E Type Rating Case Color Maximum Circuit Current (A) Connector 30 A Pink 15 Connector 40 A Green 20 Bolted 50 A Red 25 Bolted 60 A Yellow 30 Bolted 80 A Black 40