Isuzu — Isuzu N Series Training Manual

Relay Specification, Configuration and Inspection Name/ Color Rated voltage/ Coil resistance Internal circuit Name/ Color Rated voltage/ Coil resistance Internal circuit MR5C (1T)/ Black 12 V/ Approx. 90 Ω Minimum operating voltage: 7 V at 25°C (77°F) MR82C/ White label 12 V/ Approx. 23 Ω Minimum operating voltage: 7 V at 20°C (68°F) MR5C (1T)/ Brown 12 V/ Approx. 90 Ω Minimum operating voltage: 10.5 V at 25°C (77°F) N8A0431E N8A0433E MR5C (1T)/ Green 24 V/ Approx. 266 Ω Minimum operating voltage: 16 V at 25°C (77°F) MR82C/ Green label 24 V/ Approx. 100 Ω Minimum operating voltage: 16 V at 20°C (68°F) 1 2 3 4 5 N8A0432E N8A0434E MR5C (1T)/ Grey 24 V/ Approx. 266 Ω Minimum operating voltage:

20 V at 25°C (77°F) (connector face) (connector face) Inspec- tion The way Check to see if there is any conti- nuity between the relay terminals. Inspec- tion The way Check to see if there is any conti- nuity between the relay terminals.

Result (When no voltage is applied relay terminals 2 -4) 3 -5 → continuity 1 -5 → No continuity Inspection Result (When no voltage is applied relay terminals 4 -5) 2 -3 → No continuity Normal Normal Abnormal (When minimum operat- ing voltage is applied relay terminals between 2 -4) 3 -5 → continuity 1 -5 → No continuity Abnormal (When minimum operat- ing voltage is applied relay terminals between 4 -5) 2 -3 → No continuity Normal (When minimum operat- ing voltage is applied relay terminals between 2 -4) 3 -5 → No continuity 1 -5 → continuity Normal (When minimum operat- ing voltage is applied relay terminals between 4 -5) 2 -3 → continuity