When handling, do not hold the pipe of the upper EHCU. Never loosen the bolts and nuts of the EHCU body. If loosened, that EHCU must not be used anymore. 1 1. Cover Remove the cover. 2. Harness connector If the harness is fixed to the EHCU bracket, loosen the fixing clip. 2 3 1 4 2 N5A2041E Legend 1. Lever lock 2. Lever 3. Lock portion (A portion) 4. Housing 3 Operate the lever. 4 Notice: Operate the lever till the lever becomes heavy. Then change the force direction to the downward of the con- nector. (See illustration.) Applying force to the EHCU- side may damage the connector. N5A2040E Legend 1. Lever 2. Lever lock 3. Clip 4. Fixed to EHCU bracket. 1 Unlock the connector.
Pull down the lever lock to the unlock position. 2 Notice: Make sure the lock portion (A portion) is in the unlock position. 3 N5A2042E Legend 1. Lever 2. Lever operation (rotation direction) 3. Force applied direction when operating lever