Move the connector to the opposite side of the EHCU to remove. 1. Bracket Install the bracket to the frame if it has been re- moved. Notice: With the lever in stop position, make sure that the lever surface (lock portion side) is almost perpendicular to the connector before removing the connector. 2. EHCU Install the EHCU to the bracket. 3. EHCU fixing nut Install the EHCU fixing nuts. 1 Tighten: Nut to 22 N m (2.2 kg m / 16.2 lb ft) 3 2 4. Brake pipe Install the brake pipe. Tighten: Brake pipe to 16 N m (1.6 kg m / 11.8 lb ft) 3 5. Harness connector Align the harness-side connector with the EHCU-side connector. EHCU Harness N5A2043E 1 Legend 1. Lever 2. Connector 3. Lever lock 2 3 3.
Brake pipe 5 Disconnect the six brake pipes. 4. EHCU fixing nut Disconnect the three nuts fixing the EHCU. 5. EHCU Remove the EHCU. 6. Bracket 4 N5A2044E Remove the bracket. Legend 1. EHCU-side connector 2. Lever 3. Housing 4. Harness 5. Lever lock Installation CAUTION: Be sure to use ground bolt to install the ground. Make sure there is no dust or foreign materials in and around the pipe connection. Insert the harness-side connector to the EHCU- side connector. Be careful that the pipe is connect to correctly. After EHCU installation, bleed air from the brake system completely. Remove the fuse (FL-9 (40A)) of ABS to deactivate the ABS before air bleeding operation. Notice:
The lever moves approx. 30° when the connector is in- serted. Be sure to use fresh specified brake fluid.