Cooling System Item Service Standard Service Limit Water Pump External appearance Check the following: • Cracks and damages of the pump body • Cracks and corrosion of the impeller • Water leak from the seal unit When an abnormal condition is found, replace the water pump as an assembly. Seal Unit Push the fan center in the radial direction while rotating it and check the seal unit for any excessive play or abnormal sound. When there is any abnormal condition found, replace the water pump as an assembly. Delivery Volume lit (US / UK gal) / min 200 or more Water Pump Speed: 3,300 rpm Water Temperature: 80 ± 2°C (176 ± 3.6°F) Fan Drive Belt Tension mm (in) 8 — 12 (0.31 — 0.47) ...
New belt 10 — 14 (0.39 — 0.55) ... Reuse belt Depress the drive belt mid-portion with a 98N (10kg / 22Ib) force Thermostat With Jiggle Valve Valve Initial Open- °C (°F) ing Temperature 85 ± 1.5 (185 ± 2.7) Valve Lift At 100°C mm (in) (212°F) 8 (0.31) or more Thermostat With-Out Jiggle Valve Valve Initial Open- °C (°F) ing Temperature 82 ± 1.5 (177 — 182) Valve Lift At 95°C mm (in) (203°F) 8 (0.31) or more Radiator External appearance • Check the radiator for any corrosion, water leak, fin dam- age, or clogging. When there is any abnormal condition found, correct the radiator or replace it. • When deterioration, cracking or water leak is found in the rubber hose, replace the rubber hose.
Pressure Valve kPa (kg/cm2/ Opening Pressure psi) 103.0 ± 14.7 (1.05 ± 0.15 / 14.9 ± 2.1) Vacuum Valve kPa (kg/cm2/ Opening Pressure psi) 1.0 — 4.9 (0.01 — 0.05 / 0.14 — 0.71) Cooling Fan Cooling Fan Pulley rpm Speed 3,900 Rotate the fan by hand, and when it doesn’t rotate smoothly, or when there is oil leak from the fan clutch, replace the fan clutch. Cold Condition (Bi- rpm metal lower than 40°C (104°F) 900 or lower Hot Condition (Bi- rpm metal higher than 70°C (158°F) 3,300 ± 150 Pulley Ratio (Crankshaft/Fan) 175 / 151