Fuel System Engine Electrical Item Service Standard Service Limit Fuel Feed Pump Suction capacity The suction must be completed in 25 times or less. Priming Pump Speed: 60 — 100 times/minute Pipe Inside Diameter: 8mm (0.31in) Suction Pipe Length: 2,000mm (78.7 in) Suction Height: 1,000mm (39.4in) Injection Nozzle Spray Condition • The spray must be fine and uniform. • The injection must be directed in the center direction with no stray spray. • The spray from each nozzle hole must be uniform Item Service Standard Service Limit Generator Ball bearing When it doesn’t rotate smoothly or is giving out an abnor- mal sound, or when there is an oil leak from the seal, replace it.
Slip Ring Diameter mm (in) Nominal size 31.6 (1.244) 30.6 Rotor Coil Resis- Ω tance Nominal resistance 12.6 When the resis- tance differs largely from the standard value, or when a poor insulation is found, replace it.
Coil Insulation MΩ Resistance 1 or more (500 volt megger tester) Stator Coil Resis- Ω tance Nominal resistance 0.17 (Between coil end and each coil end) Coil Insulation MΩ Resistance 1 or more (500 volt megger tester) Brush Length mm (in) Nominal size 20 (0.79) 6 (0.24) IC Voltage Regulator Rectifier The rectifier is normal when there is continuity with the tester - terminal con- nected to “B” (battery) terminal and the + terminal to the rectifier holder, and when there is no continuity with their connections reversed. When there is conti- nuity in both direc- tions, or when there is no continuity in both directions, replace the rectifier.
Battery Power V LR 250 — 504 (24V - 60A) LR 250 — 508B (24V - 50A) DENSO (12V - 35A) 28 — 29 28 — 29 27.8 — 28.8 LR 250 — 510 (24V - 50A) LR 180 — 510 (12V - 80A) 28 — 29 14.1 — 14.7