Isuzu — Isuzu N Series Training Manual

9. Attach the injection nozzle holder to the injection nozzle tester. 10. Apply pressure to the nozzle tester to check that the injection nozzle opens at the specified pres- sure. If the injection nozzle does not open at the speci- fied pressure, install or remove the appropriate number or adjusting shims to adjust it. Removing or installing one shim will increase or decrease the nozzle opening pressure approxi- mately 370 kPa (3.77 kg/cm 2 / 53.6 psi). 4. Operate the priming pump several times again and check for fuel leak. 5. Tighten the air bleeding plug. 6. Make sure that the warning light in the instrument panel is off.

(Except 4HE1-TC model) Cooling System Coolant Level Check the coolant level and replenish the radiator re- serve tank if necessary. If the coolant level falls below the “MIN” line, carefully check the cooling system for leakage. Then add enough coolant to bring the level up to the “MAX” line. Air Bleeding (Except 4HF1-2 model only) Above works refer to “FUEL SYSTEM” in this section. Air Bleeding (4HF1-2 model only) 1. Actuate the priming pump (1) to send the air in the fuel system to the injection pump. 2. Loosen the sedimenter air bleeding plug (2) and operate the priming pump until no bubbles appear. 3. Tighten the air bleeding plug (2) completely. N6A0033E Notice:

Do not overfill the reserve tank. Remove the radiator filler cap only when absolutely nec- essary. Always check the coolant level when the engine is cold. Always refer to the chart at the left to determine the cor- rect cooling water to antifreeze solution mixing ratio. N6A0032E 4. Try to start the engine. If the engine is not started within 10 seconds, air bleeding should be conduct- ed once again. 5. Check that there is no fuel leak, and then tighten the priming pump completely. Water Drain If more water than specified has collected, the warning light is lit. Under this condition, follow the following water drain procedure: 1.

Place a container (Approximately 0.2 liters capaci- ty) beneath the drain plug on the separator. 2. Loosen the drain plug and air bleeding plug. 3. After draining, tighten the drain plug. Adjust Shim Arailability mm (in) Range 0.5 — 1.5 (0.02 — 0.06) Increment 0.025 (0.001) Total Number of Shims 41