N6A0841E 4. Injection Nozzle Assembly Mark the nozzle holder assemblies fitting positions by tagging each nozzle holder assembly with the cylinder number from which it was removed. N6A0843E Spray Pattern Check the spray pattern Refer to the illustration. Spray Condition Correct (1) Incorrect (Dripping) (3) If the spray condition is bad, the injection nozzle must be replaced or adjusted. Incorrect (Restrictions in orifice) (2) N6A0842E Inspection Before disassembling the injection nozzle assembly, check nozzle opening pressure, spray pattern, chatter and oil leakage. Opening Pressure Use a nozzle tester to check the injection nozzle open- ing pressure.
If the opening pressure is above or below the specified value, the injection nozzle must be replaced or adjusted. N6A0029E Injection Nozzle Opening MPa (kg/cm2/psi) Pressure 4HF1/4HF1-2/4HG1 18.1 (185/2,631) 4HE1-TC 21.6 (220/3,128) 4HG1-T 1st 18.1 (185/2,631) 2nd 21.1 (215/3,057)