ENGINE ELECTRICAL BATTERY General Description There are six battery fluid caps at the top of the battery. The battery is completely sealed except for the six small vent holes at the side. These vent holes permit the es- cape of small amounts of gas generated by the battery. This type of battery has the following advantages over conventional batteries: 1. There is no need to add water during the entire ser- vice life of the battery. 2. The battery protects itself against overcharging. The battery will refuse to accept an excessive charge. (A conventional battery will accept an excessive charge, resulting in gassing and loss of battery flu- id.) 3.
The battery is much less vulnerable to self-dis- charge than a conventional type battery. N6A0983E Diagnosis Visual Inspection Legend 1. Battery 2. Upper level 3. Lower level Inspect the battery for obvious physical damage, such as a cracked or broken case, which would permit elec- trolyte loss. Replace the battery if obvious physical damage is dis- covered during inspection. Check for any other physical damage and correct it as necessary. If not, proceed to “Hydrometer check”. Voltage Check 1. Put voltmeter test leads to battery terminals. a. VOLTAGE IS 12.4V OR ABOVE - Go to “Load test”. b. VOLTAGE IS UNDER 12.4V - Go to procedure 2 below. 2.
Determine fast charge amperage from specifica- tion. (See Main Data and Specifications in this section). Fast charge battery for 30 minutes at amperage rate no higher than specified value. Take voltage and amperage readings after charge. a. VOLTAGE IS ABOVE 16V AT BELOW 1/3 OF AMPERAGE RATE - Replace battery. b. VOLTAGE IS ABOVE 16V AT ABOVE 1/3 OF AMPERAGE RATE - Drop charging voltage to 15V and charge for 10 — 15 hours. Then go to “Load test”. c. VOLTAGE IS BETWEEN 12V AND 16V - Con- tinue charging at the same rate for an additional 3-1/2 hours. Then go to “Load test”. d. VOLTAGE IS BELOW 12V - Replace battery.
Hydrometer Check There is a built-in hydrometer (Charge test indicator) at the top of the battery. It is designed to be used during di- agnostic procedures. Before trying to read the hydrometer, carefully clean the upper battery surface. If your work area is poorly lit, additional light may be nec- essary to read the hydrometer. a. BLUE RING OR DOT VISIBLE - Go to “Voltage check”. b. BLUE RING OR DOT NOT VISIBLE - Go to “Fluid level check”. Fluid Level Check The fluid level should be between the upper level line and lower level line on side of the battery. a. CORRECT FLUID LEVEL - Charge the battery. b. BELOW LOWER LEVEL - Replace battery. Load Test 1.
Connect a voltmeter and a battery load tester across the battery terminals. 2. Apply 300 ampere load for 15 seconds to remove surface charge from the battery. Remove load.