If the mica segment depth is less than the standard but more than the limit, the commutator may be re- ground. If the mica segment depth is less than the limit, the commutator must be replaced. N6A1002E Inspection and Repair Make the necessary adjustments, repairs, and part re- placements if excessive wear or damage is discovered during inspection. Armature 1. Measure the commutator run-out. Replace the commutator if the measured run-out exceeds the specified limit. N6A1005E Legend 1. Insulator 2. Commutator segments 4. Measure the commutator outside diameter. N6A1004E 2. Check the commutator mica segments for exces- sive wear. 3. Measure the mica segment depth.
N6A1006E Mica Segment Depth mm (in) Standard Limit 0.5 — 0.8 (0.020 — 0.031) 0.2 (0.008) Commutator Run-Out mm (in) Standard Limit 0.05 (0.002) or less 0.2 (0.008)