1) Hold one probe of the circuit tester against the commutator segment. 2) Hold the other circuit tester probe against the armature core. If the circuit tester indicates continuity, the arma- ture is grounded. The armature must be replaced. 7. Use the circuit tester to check the armature for con- tinuity. If the measured outside diameter is less than the specified limit, the commutator must be replaced. 5. Test the armature for short circuiting. N6A1009E 1) Hold the circuit tester probes against two arma- ture core segments. 2) Repeat Step 1 at different segments of the ar- mature core. There should be continuity between all segments of the armature core.
If there is not, the armature must be replaced. N6A1007E a. Place the armature in a growler tester. b. Hold a hacksaw blade against the armature core. If the armature has a short circuit, the hacksaw blade will vibrate. Replace the armature if there is a short circuit. 6. Use a circuit tester to check the armature for grounding. Yoke 1. Use a circuit tester to check the field winding ground. N6A1010E N6A1008E Commutator Outside Diameter mm (in) Model Yoke Diameter Standard Limit S25-163C φ80 36.5 (1.437) 35.5 (1.398) S25-305C φ90 38.0 (1.496) 36.6 (1.441)