N6A1090E Legend 1. Vacuum pump tester 2. Intake 4HE1-TC LR180-510 (12-50A) 6. On-vehicle test of the vacuum pump Install the generator to the engine. With the engine idling, check to see if oil is be- ing discharged sufficiently from the exhaust side of the vacuum pump. Idle the engine until the engine oil temperature gets to the range of 70 — 80 ° C (158 — 176 ° F). Connect the pipe only to the suction side of the vacuum pump tester, and conduct the test in the same manner as in the unit test. When the resulting value is outside the specified range, re-check the vacuum pump. Item Performance Specifications Vacuum characteristic 5000 rpm — 66.7 kPa (500 mmHg / 9.67 psi) Less than 4 sec. Max.
5000 rpm More than 90.7 kPa (680 mmHg / 13.15 psi) Vacuum- down perfor- mance Valve of vacuum- down 15 sec. after the vacuum pump is stopped at 53.3 kPa (400 mmHg / 7.73 psi). Less than 2.67 kPa (20 mmHg / 0.39 psi) Test condition Oil used Mobil oil #30 Oil tempera- ture 75±5°C (167±41°F) Oil pressure 441 kPa (4.5 kg/cm2 / 63.96 psi) Item Performance Specifications Vacuum characteristic 5000 rpm — 66.7 kPa (500 mmHg / 9.67 psi) Less than 10 sec. Max. 5000 rpm More than 90.7 kPa (680 mmHg / 13.15 psi) Vacuum- down perfor- mance Valve of vacuum- down 15 sec. after the vacuum pump is stopped at 53.3 kPa (400 mmHg / 7.73 psi).
Less than 2.67 kPa (20 mmHg / 0.39 psi) Test condition Oil used Mobil oil #30 Oil tempera- ture 75±5°C (167±41°F) Oil pressure 441 kPa (4.5 kg/cm2 / 63.96 psi)