Increase the number of the generator rotations gradually until the reading of the voltmeter indi- cates 27V. Measure the number of rotations at this time. 4. Output current measurement Pour about 20 liter (5.28 US gal/4.40 UK gal) of engine oil into the vacuum pump tester. Increase the generator rotations gradually, and check to see if the engine oil is fully circulated by discharging oil from the exhaust side of the vacuum pump. Close the release valve and measure the “vac- uum characteristic” and the “vacuum drop char- acteristic (air tight characteristic)”. Then check the obtained values based on the following ta- ble.
N6A1082E Set the resistance of the variable resistor at the minimum, and rotate the generator with SW1 and SW2 closed. While keeping the voltage steady at 27V after adjusting the variable resistor, read the indicat- ed value of the ammeter at the generator rota- tion of 5,000 rpm. Current at 27V with 5,000 rpm = 35A or more (for 35A specification) Current at 27V with 5,000 rpm = 45A or more (for 50A specification) 5. Unit test of vacuum pump N6A1662E With a pipe arrangement as shown in the illus- tration, use the vacuum pump tester to conduct the measurement. N6A1663E N6A1085E