Isuzu — Isuzu N Series Training Manual

Inspection 1. Thermosensor (Engine Coolant Temperature) Soak the temperature sensitive part of a ther- mosensor in the water, and while changing the wa- ter temperature, make sure the resistance is changed as the following graph shows: N6A1256E Legend 1. Port 2. Pin Connect battery voltage between EVRV connector terminals and make sure of the continuity between the ports. N6A1254E N6A1255E N6A1257E Legend 1. Resistance (k Ω ) 2. ECT ° F ( ° C) Legend 1. Vacuum port 2. Electronic Vacuum Regulating Valve (EVRV) (Equipped with Exhaust Gas Recirculation (EGR) and Variable Swirl System (VSS)) Resistance Check Check the resistance between the EVRV connec- tor terminals using a circuit tester.

Cold Resistance: 12 ± 1 ( Ω ) Airtight Check Apply negative pressure to the negative pressure input port as illustrated on the left. Although there is leakage, it is no problem if the negative pressure rises to -46.7 kPa (-350 mmHg / -6.77 psi) or more. Caution: When measuring resistance with a circuit tester, be careful not to damage or deform the terminals.