11. Electric Wiring 11.2.4 Section area and resistance of electric wire (1) Allowable maximum cable length Terminal resistance is not included. Note1) Allowable maximum resistance of Battery cable Note2) Allowable maximum resistance of Starting motor circuit (2) Terminal resistance Generally, a terminal resistance is 15m per screw setting. This resistance should be included in allowable maximum resistance when the cable length is planned. per coupler and 0 184 Cable size mm2 Cable construction Resistance ( /m) 2m Note1 (m) 20m Ref. (m) 50m Note2 (m) Element No. Cable dia.
3 41 0.32 0.005590 0.36 3.58 8.94 5 65 0.32 0.003520 0.57 5.68 14.20 8 50 0.45 0.002320 0.86 8.62 21.55 15 84 0.45 0.001380 1.45 14.49 36.23 20 41 0.80 0.000887 2.25 22.55 56.37 30 70 0.80 0.000520 3.85 38.46 96.15 40 85 0.80 0.000428 4.67 46.73 116.82 50 108 0.80 0.000337 5.93 59.35 148.37 60 127 0.80 0.000287 6.97 69.69 174.22 85 169 0.80 0.000215 9.30 93.02 232.56 100 217 0.80 0.000168 11.90 119.05 297.62