Komatsu — 2.7 Thermostat Inspection

2. Inspection and Adjustment 2.6 Radiator cap inspection Install the radiator cap on the cap tester. Set the tester pressure to 0.09 0.15kgf/cm 2 ) and see that the cap is opened. If the cap does not open, replace the cap since it is abnormal. 0.015MPa (0.9 2.7 Thermostat Inspection Place the thermostat in a container filled with water. Heat it while measuring the water temperature, and see that the thermostat is actuated at temperature of following table. * Valve opening temperature is carved on the flange. 51 Model Valve opening Temperature (deg C)* Full open lift (Temperature) (mm) All models 69.5 72.5 8 or more (85deg C)