4 Gauges early 6LY3/SY early 6ly3/SY Series engines Serial Gauges (i2000 Series - discontinued) These gauges were used on some early 6LY3 installations. They require a separate module (i2001x) for each engine to decode the CAN Bus information for the gauges. They can be identified by the wire, with a connector on the end, coming out of the back of each gauge (see rear view below). Specifications Operating Temperature: -18°C (0°F) to +70°C (+158°F). Storage Temperature: -40°C (-40°F) to +80°C (+176°F). Humidity: Perform 100-hour humidity test per Section 24.7.4 of ABYC P-24. Salt Spray Atmosphere: Perform 300 hours of salt fog per ASTM B117. Water Resistance (Hose Down):
The gauges and SIM shall not allow any water to enter any of the enclosures when exposed to 100 liters of water per minute for three minutes per component using a 12.5 mm nozzle. The water shall be directed to all exposed surfaces during the three-minute test. SAE J1455 Section 4.4.3 2” Gauge rear view © 2011 Yanmar Marine International • Rev. 2.0 4:28 Yanmar Electronic Control Systems Technical Manual