8 Networks Understanding – The following are typical key readings: • Bus Load 1 – 20% • Error Frames per Second Less than 5 for any short time and 0 or 1 on any longer term basis • Total Errors Less than 10 one minute after startup • Voltage 9 – 16 volts with 12 – 14 being typical Note: Additional diagnostic information on this screen is covered in “Section 15 - Troubleshooting.” Network Nodes Display The Network Units Display Screen shows Yanmar and Teleflex units that have claimed an address on the bus. From the information in the claimed message name (Device Class, Function, and Instance Fields) the type of model number of the unit will be determined.
(The specific model may not be indicated, but it will give a general model of the type of the unit, e.g. i813x.) The information displayed consists of: Node Address Manufacturer’s Code - (All mfg’s codes will be shown, but only Yanmar and Teleflex units will show the mfg’s name) Manufacturers Model Info - On some units the ending letter signifies the following: P - Port S - Starboard C - Center Engine Buttons: “Down” Arrow moves menu selection down. “Up” Arrow moves menu selection up. “Back” moves back to previous menu. Note: Additional diagnostic information on this screen is covered in “Section 15 - Troubleshooting.” Manufacturers’ codes may be found on the NMEA website: www.nmea.org.
© 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 8:17