SEBU8598 35 Engine Starting Starting with Jump Start Cables If the engine is operated with a low load, the engine will reach normal operating temperature sooner than idling the engine with no load. When the engine is idled in cold weather, increase the engine rpm to approximately 1000 to 1200 rpm in order to warm up the engine more quickly. Do not exceed the recommended rpm in order to increase the speed of the warm-up. Limit unnecessary idle time to 10 minutes. 2. If a wire is loose, push the wire back into the connector. Pull the wire again in order to ensure that the wire is secure. 3. Start the engine. If the engine does not start, consult the nearest Caterpillar dealer for assistance.
i02049673 Starting with Jump Start Cables (Do Not Use This Procedure in Hazardous Locations that have Explosive Atmospheres) Starting Problems An occasional starting problem may be caused by one of the following items: Low battery charge Lack of fuel Problem with the wiring harness If the engine fuel system has been run dry, fill the fuel tank and prime the fuel system. Refer to the Operation and Maintenance Manual, “Fuel System - Prime” topic (Maintenance Section). SMCS Code: 1000; 1401; 1402; 1900 The connection of battery cables to a battery and the disconnection of battery cables from a battery may cause an explosion which may result in in- jury or death.
The connection and the disconnec- tion of other electrical equipment may also cause an explosion which may result in injury or death. The procedures for the connection and the dis- connection of battery cables and other electrical equipment should only be performed in a nonex- plosive atmosphere. If the other problems are suspected, perform the appropriate procedure in order to start the engine. Problems with the Wiring Harness Improper jump start cable connections can cause an explosion resulting in personal injury. Prevent sparks near the batteries. Sparks could cause vapors to explode. Do not allow jump start cable ends to contact each other or the engine.
If the installation is not equipped with a backup battery system, it may be necessary to start the engine from an external electrical source. First, determine the reason that it is necessary to start with power from an external source. Refer to Special Instruction, SEHS7768, “Use of the 6V-2150 Starting/ Charging Analyzer”. Illustration 29 g01248812 ECM Connector J2/P2 Many batteries which are considered unusable are still rechargeable. After jump starting, the alternator may not be able to fully recharge batteries that are severely discharged. The batteries must be charged to the proper voltage with a battery charger.
For information on testing and charging, refer to the Special Instruction, SEHS7633, “Battery Test Procedure”. Locate the ECM. Check the connector in order to ensure that the connector is secure. Lightly pull each of the wires in the chassis harness. 1. Pull each wire with approximately 4.5 kg (10 lb) of force. The wire should remain in the connector.