36 SEBU8598 Engine Starting After Starting Engine NOTICE Using a battery source with the same voltage as the electric starting motor. Use ONLY equal voltage for jump starting. The use of higher voltage will damage the electrical system. Check for fluid or air leaks at idle rpm and at one- half full rpm (no load on the engine) before operating the engine under load. Operating the engine at idle and at one-half full rpm with no load is not possible in some applications. Do not reverse the battery cables. The alternator can be damaged. Attach ground cable last and remove first. Operate the engine at low idle until all systems achieve operating temperatures.
Check all gauges during the warm-up period. When using an external electrical source to start the engine, turn the generator set control switch to the OFF position. Turn all electrical accessories OFF before attaching the jump start cables. Note: Gauge readings should be observed and the data should be recorded frequently while the engine is operating. Comparing the data over time will help to determine normal readings for each gauge. Comparing data over time will also help detect abnormal operating developments. Significant changes in the readings should be investigated.
Ensure that the main power switch is in the OFF posi- tion before attaching the jump start cables to the en- gine being started. Extended Idle at Cold Ambient Temperature 1. Turn the start switch on the stalled engine to the OFF position. Turn off all accessories. The engine may automatically change speeds when the engine is idling in cold ambient temperatures (typically less than 0° C (32° F) for extended periods. The purpose of the automatic speed change is threefold: to maintain the desired operation of the NOx reduction system, to maintain the desired operation of the regeneration system and to keep the engine coolant warm. The engine speed may rise to 1600 rpm for as long as 20 minutes.
2. Connect one positive end of the jump start cable to the positive cable terminal of the discharged battery. Connect the other positive end of the jump start cable to the positive cable terminal of the electrical source. 3. Connect one negative end of the jump start cable to the negative cable terminal of the electrical source. Connect the other negative end of the jump start cable to the engine block or to the chassis ground. This procedure helps to prevent potential sparks from igniting combustible gases that are produced by some batteries. The high exhaust system temperature lamp may illuminate during extended idling conditions.
This illumination signals that a diesel particulate filter (DPF) regeneration is in progress. Regenerations during cold ambient extended idling may only last up to 10 minutes. 4. Charge the batteries. The engine will not continue to run after starting if the batteries have not been charged. 5. Start the engine. 6. Immediately after the stalled engine is started, disconnect the jump start cables in reverse order. Refer to the Electrical Schematic for your engine. Consult your Caterpillar dealer for more information. i05359363 After Starting Engine SMCS Code: 1000 Note: In temperatures from 0 to 60°C (32 to 140°F), the warm-up time is approximately 3 minutes.
In temperatures below 0°C (32°F), additional warm-up time may be required. When the engine is idling during warm-up, observe the following conditions: