Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

SEBU8598 39 Engine Operation Diesel Particulate Filter Regeneration FORCE REGENERATION – Press and hold in the top of the switch for 3 seconds to start regeneration. Soot Level Monitoring DISABLE REGENERATION – Press and hold in the bottom of the switch for 3 seconds to disable regeneration. Note: To re-enable the regeneration, cycle the engine START SWITCH KEY or press and hold in the FORCE REGENERATION switch for 2 seconds. Illustration 33 g02228033 Note: If the engine START SWITCH KEY is cycled while the regeneration system is disabled via the DISABLE REGENERATION switch, press and hold in the DISABLE REGENERATION switch for 3 seconds to reinitiate the disable regeneration.

The soot level monitor indicates the level of soot that has accumulated within the DPF. The five marks on the monitor represent the percentage of soot within the DPF. The first mark indicates 0% soot level. The second mark indicates 25% soot level. The third mark indicates 50% soot level. The fourth mark indicates 75% soot level. The last mark indicates 100% soot level. The soot level monitor may be used to optimize DPF regenerations based upon the work cycle of the engine. If operating conditions do not allow for automatic regeneration, a manual regeneration should be performed before the soot level gauge indicates 100% OK to Elevate Idle Switch Note:

The soot level monitor may not be applied to all engines. Some OEM's may also use a different method of displaying soot load of the DPF. Refer to OEM operation manual for explanation. Modes of Regeneration Automatic The engine control module (ECM) uses multiple electrical inputs from the engine to determine the best time for an automatic regeneration. An automatic regeneration may take place throughout the operating cycle of the engine. An automatic regeneration may start when the engine is at the low idle speed or when the engine is at normal operating speed. The HEST indicator lamp is illuminated when a regeneration is being performed.

Illustration 32 g02333673 OK to Elevate Idle Switch switch The position of the OK to Elevate Idle Switch switch in the side view is the LOCKED position. OK to Elevate Idle Switch – Pressing in and locking the OK to Elevate Idle switch enables the engine ECM to elevate engine speed automatically when needed. For example, if the engine is running at low idle and a DPF regeneration is activated, having the OK to Elevate Idle switch in the LOCKED position will allow the engine speed to increase in order for the DPF regeneration to occur. If an automatic regeneration starts while the engine is at the low idle speed, the engine may be returned to normal work at any time.

Returning to normal work may stop the regeneration. The ECM will continue to monitor inputs to determine the best time to restart the regeneration. Interruptions of the regeneration are acceptable. If a regeneration needs to be stopped for any reason, press the DISABLE REGENERATION switch or turn off the engine. Note: This switch is only available on engines with instrument panels supplied by Cat. Note: An automatic adjustment of engine speed may be noticed during an automatic regeneration. If the engine is taken to a low idle speed while a regeneration is occurring, the engine speed may remain elevated in order for the regeneration to continue.