Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

42 SEBU8598 Cold Weather Operation Radiator Restrictions Cold Weather Operation There are three major differences between No. 1 and No. 2 diesel fuel. No. 1 diesel fuel has the following properties: i01646447 Radiator Restrictions Lower cloud point SMCS Code: 1353; 1396 Lower pour point Caterpillar discourages the use of airflow restriction devices that are mounted in front of radiators. Airflow restriction can cause the following conditions: Lower rating of kJ (BTU) per unit volume of fuel When No. 1 diesel fuel is used, a decrease in power and in fuel efficiency may be noticed. Other operating effects should not be experienced.

High exhaust temperatures Power loss The cloud point is the temperature when a cloud of wax crystals begins to form in the fuel. These crystals can cause the fuel filters to plug. The pour point is the temperature when diesel fuel will thicken. The diesel fuel becomes more resistant to flow through fuel pumps and through fuel lines. Excessive fan usage Reduction in fuel economy If an airflow restriction device must be used, the device should have a permanent opening directly in line with the fan hub. A centered opening that is directly in line with the fan hub is specified in order to prevent an interrupted airflow on the fan blades.

Interrupted airflow on the fan blades could cause a fan failure. Be aware of these values when diesel fuel is purchased. Anticipate the average ambient temperature for the engine area. Engines that are fueled in one climate may not operate well if the engines are moved to another climate. Problems can result due to changes in temperature. Caterpillar recommends a warning device for the inlet manifold temperature and/or the installation of an inlet air temperature gauge. The warning device for the inlet manifold temperature should be set at 75 °C (167 °F). The inlet manifold air temperature should not exceed 75 °C (167 °F).

Temperatures that exceed this limit can cause power loss and potential engine damage. Before troubleshooting for low power or for poor performance during cold weather, check the type of fuel that is being used. i03480664 Fuel Related Components in Cold Weather i03895851 Fuel and the Effect from Cold Weather SMCS Code: 1000; 1250; 1280 Fuel Tanks Condensation can form in partially filled fuel tanks. Top off the fuel tanks after you operate the engine. SMCS Code: 1000; 1250; 1280 Fuel tanks should contain some provision for draining water and sediment from the bottom of the tanks. Some fuel tanks use supply pipes that allow water and sediment to settle below the end of the fuel supply pipe.

The following fuels are the grades that are available for Caterpillar engines: No. 1 No. 2 Some fuel tanks use supply lines that take fuel directly from the bottom of the tank. If the engine is equipped with this system, regular maintenance of the fuel system filter is important. Blend of No. 1 and No. 2 No. 2 diesel fuel is the most commonly used fuel. Either No. 1 diesel fuel or a blend of No. 1 and No. 2 is best suited for cold weather operation. Fuel Filters Note: No. 2 diesel fuel can begin to form crystals at approximately −9° C (15° F). Cold fuel may contain wax which will block the fuel filters. One of the following changes can prevent problems in many conditions:

a change in the location of fuel filters and/or supply lines and the addition of insulation. Quantities of No. 1 diesel fuel are limited. No. 1 diesel fuels are usually available during the months of the winter in the colder climates. During cold weather operation, if No. 1 diesel fuel is not available, use No. 2 diesel fuel, if necessary.