Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

44 SEBU8598 Engine Stopping Manual Stop Procedure Engine Stopping If necessary, perform minor adjustments. Repair any leaks and tighten any loose bolts. i04315380 Manual Stop Procedure Note the service hour meter reading. Perform the maintenance that is in the Operation and Maintenance Manual, “Maintenance Interval Schedule”. SMCS Code: 1000; 7418 Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill the fuel tank. NOTICE Stopping the engine immediately after it has been working under load can result in overheating and ac- celerated wear of the engine components. Allow the engine to cool. Check the coolant level.

Maintain the cooling system at 13 mm (0.5 inch) from the bottom of the pipe for filling. If the engine has been operating at high rpm and/or high loads, run at low idle for at least three minutes to reduce and stabilize internal engine temperature be- fore stopping the engine. Note: Only use coolant that is recommended in this Operation and Maintenance Manual, “Fluid Recommendations” article. Failure to do so may result in engine damage. Avoiding hot engine shutdowns will maximize turbo- charger shaft and bearing life. If freezing temperatures are expected, check the coolant for proper antifreeze protection.

The cooling system must be protected against freezing to the lowest expected outside temperature. Add the proper coolant/water mixture, if necessary. Note: Individual applications have different control systems. Ensure that the shutoff procedures are understood. Use the following general guidelines in order to stop the engine. Perform all required periodic maintenance on all driven equipment. This maintenance is outlined in the instructions from the OEM. 1. Remove the load from the engine so that the engine has no more than 30% power. 2. Run the engine at the programmed low idle speed for at least 3 minutes. 3. After the cool down period, turn the start switch to the OFF position.

i04137729 After Stopping Engine SMCS Code: 1000 Note: After operation, allow 10 minutes for the engine oil to return to the oil pan before checking the engine oil level. Check the crankcase oil level. Maintain the oil level between the ADD mark and the FULL mark on the oil level gauge. Note: Only use oil that is recommended in this Operation and Maintenance Manual, “Fluid Recommendations” article. Failure to do so may result in engine damage.