Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

SEBU8598 65 Maintenance Recommendations Coolant (DEAC) - Change 1. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. 2. Open the cooling system drain valve. Allow the coolant to drain. NOTICE Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. For information regarding the disposal and the recycling of used coolant, consult your Cat dealer or consult Cat Dealer Service Tools Group :

Outside Illinois 1-800-542-TOOL Inside Illinois 1-800-541-TOOL Canada 1-800-523-TOOL International 1-309-578-7372 Flush Illustration 48 g02351659 The cooling system drain valve is towards the bottom of the radiator. 1. Flush the cooling system with clean water in order to remove any debris. Drain 2. Close the drain valve. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. Pressurized System: Hot coolant can cause seri- ous burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure. 3.

Fill the cooling system with a mixture of clean water and Cat Fast Acting Cooling System Cleaner. Add 0.5 L (1 pt) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap. NOTICE Care must be taken to ensure that fluids are con- tained during performance of inspection, mainte- nance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. 4. Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).

NOTICE Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components. Refer to Special Publication, NENG2500, “Caterpillar Dealer Service Tool Catalog” or refer to Special Publi- cation, PECJ0003, “Caterpillar Shop Supplies and Tools Catalog” for tools and supplies suitable to col- lect and contain fluids on Caterpillar products. To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone. Dispose of all fluids according to local regulations and mandates.