78 SEBU8598 Maintenance Recommendations Engine Oil Sample - Obtain i04237495 Engine Oil Sample - Obtain NOTICE Always use a designated pump for oil sampling, and use a separate designated pump for coolant sam- pling. Using the same pump for both types of samples may contaminate the samples that are being drawn. This contaminate may cause a false analysis and an incorrect interpretation that could lead to concerns by both dealers and customers. SMCS Code: 1348-554-SM In addition to a good preventive maintenance program, Caterpillar recommends using S·O·S oil analysis at regularly scheduled intervals.
S·O·S oil analysis provides infrared analysis, which is required for determining nitration and oxidation levels. If the engine is not equipped with a sampling valve, use the 1U-5718 Vacuum Pump. The pump is designed to accept sampling bottles. Disposable tubing must be attached to the pump for insertion into the sump. Obtain the Sample and the Analysis Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin. For instructions, see Special Publication, PEGJ0047, “How To Take A Good S·O·S Oil Sample”. Consult your Cat dealer for complete information and assistance in establishing an S·O·S program for your engine.
Before you take the oil sample, complete the Label, PEEP5031 for identification of the sample. In order to help obtain the most accurate analysis, provide the following information: i05295270 Engine Oil and Filter - Change Engine model Service hours on the engine SMCS Code: 1318-510 The number of hours that have accumulated since the last oil change Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin. The amount of oil that has been added since the last oil change To ensure that the sample is representative of the oil in the crankcase, obtain a warm, mixed oil sample.
Selection of Oil Change Interval To avoid contamination of the oil samples, the tools and the supplies that are used for obtaining oil samples must be clean. Refer to this Operation and Maintenance Manual, “Fluid Recommendations” for further information about oils that may be used in Caterpillar engines. Caterpillar recommends using the sampling valve in order to obtain oil samples. The quality and the consistency of the samples are better when the sampling valve is used. The location of the sampling valve allows oil that is flowing under pressure to be obtained during normal engine operation.
Refer to this Operation and Maintenance Manual, “Severe Service Application” to determine if the oil change interval should be reduced from the normal change interval. If operating in any of the conditions or environments outlined in the Severe Service Application, use S·O·S Services oil analysis to determine the oil change interval. If S·O·S Services oil analysis is not being used, the oil change interval should be reduced to 250 hrs. Table 11 The 169-8373 Fluid Sampling Bottle is recommended for use with the sampling valve. The fluid sampling bottle includes the parts that are needed for obtaining oil samples. Instructions are also provided.
Oil Change Interval (1) Multigrade Oil Type Operating Conditions Normal Severe Service Application (continued)