Kaiyi — Kaiyi Power Train System Technical Manual

侍# Some fault codes are not applied to this machine. 3-63 Fault code (Hex) Meaning of the fault code possible reason for fault detection Reaction of the TCU Possible steps to repair 6E EEC2 timeout Timeout of CAN-message EEC2 from EEC controller ÂInterference on CAN-Bus ÂCAN wire/connector is broken  CAN wire/connector is defective and has contact to vehicle ground or battery voltage No reaction, TCU uses default signal accelerator pedal in idle position OP mode : Normal 余 Check EEC controller 余 Check wire of CAN-Bus 余 Check cable to EEC controller 71 S.C.

to battery voltage at clutch K1 The measured resistance value of the valve is out of limit, the voltage at K1 valve is too high ÂCable/connector is defective and has contact to battery voltage ÂCable/connector is defective and has contact to another regulator output of the TCU ÂRegulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check the cable from TCU to the gearbox 余 Check the connectors from TCU to the gearbox 余 Check the regulator resistance* 余 Check internal wire harness of the gearbox * See page 3-74 72 S.C.

to ground at clutch K1 The measured resistance value of the valve is out of limit, the voltage at K1 valve is too low ÂCable/connector is defective and has contact to vehicle ground ÂRegulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check the cable from TCU to the gearbox 余 Check the connectors from gearbox to TCU 余 Check the regulator resistance* 余 Check internal wire harness of the gearbox * See page 3-74 73 O.C.

at clutch K1 The measured resistance value of the valve is out of limit  Cable/connector is defective and has no contact to TCU ÂRegulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check the cable from TCU to the gearbox 余 Check the connectors from gearbox to TCU 余 Check the regulator resistance* 余 Check internal wire harness of the gearbox * See page 3-74 74 S.C.

to battery voltage at clutch K2 The measured resistance value of the valve is out of limit, the voltage at K2 valve is too high ÂCable/connector is defective and has contact to battery voltage ÂCable/connector is defective and has contact to another regulator output of the TCU ÂRegulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check the cable from TCU to the gearbox 余 Check the connectors from gearbox to TCU 余 Check the regulator resistance* 余 Check internal wire harness of the gearbox * See page 3-74 75 S.C.

to ground at clutch K2 The measured resistance value of the valve is out of limit, the voltage at K2 valve is too low ÂCable/connector is defective and has contact to vehicle ground ÂRegulator has an internal defect TCU shifts to neutral OP mode : Limp home If failure at another clutch is pending TCU shifts to neutral OP mode : TCU shutdown 余 Check the cable from TCU to the gearbox 余 Check the connectors from gearbox to TCU 余 Check the regulator resistance* 余 Check internal wire harness of the gearbox * See page 3-74