Actuator Actuator 5) 5) MEASURING OF RESISTANCE AT ACTUATOR/SENSOR AND CABLE MEASURING OF RESISTANCE AT ACTUATOR/SENSOR AND CABLE (1) (1) 1 R G 2 76043PT19 Open circuit R 12 = R 1G = R 2G = в Short cut to ground R 12 = R; R 1G = 0, R 2G = R or R 1G = R, R 2G = 0 (For S.C. to ground, G is connected to vehicle ground) Short cut to battery R 12 = R; R 1G = 0, R 2G = R or R 1G = R, R 2G = 0 (For S.C.
to battery, G is connected to battery voltage) (2) (2) Cable Cable UBat TCU P(Power supply) 1 2 Actuator/ Sensor C(Chassis) Ground 76043PT20 Open circuit R 12 = R 1P = R 1C = R 2P = R 2C = в Short cut to ground R 12 = 0; R 1C = R 2C = 0, R 1P = R 2P = в Short cut to battery R 12 = 0; R 1C = R 2C = 0, R 1P = R 2P = 0 3-74